Schurter Inductors, Chokes & Coils

Types of Inductors, Chokes & Coils

Change category view
Results: 349
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS Inductance Tolerance Maximum DC Current Termination Style Maximum Operating Temperature
Schurter Common Mode Chokes / Filters DKIP Compensat choke 15A
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 2
2 mH 15 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKIP Compensat choke 20A
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 2
1 mH 20 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKIP Compensat choke 25A
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 1
4 mH 25 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKIP Compensat choke 36A
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 1
2 mH 36 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKIP Compensat choke 50A
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 1
1 mH 50 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKLP Compensat choke 3A <60mH
Non-Stocked Lead-Time 12 Weeks
Min.: 504
Mult.: 12
30 mH - 30 %, + 50 % 3 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKLP Compensat choke 5A <60mH
Non-Stocked Lead-Time 12 Weeks
Min.: 504
Mult.: 12
10 mH 5 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKLP Compensat choke 8A <60mH
Non-Stocked Lead-Time 12 Weeks
Min.: 504
Mult.: 12
4 mH - 30 %, + 50 % 8 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKLP Compensat choke 3A <60mH
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 2
50 mH - 30 %, + 50 % 3 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKLP Compensat choke 4A <60mH
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 2
30 mH 4 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKLP Compensat choke 5A <60mH
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 2
20 mH 5 A Wire + 100 C
Schurter Common Mode Chokes / Filters DKLP Compensat choke 16A <60mH
Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 1
10 mH - 30 %, + 50 % 16 A Wire + 100 C
Schurter RF inductors - Leaded DLF Linear-Drossel 1.5A Non-Stocked Lead-Time 6 Weeks
Min.: 1
Mult.: 1
110 uH 1.5 A Radial + 125 C
Schurter RF inductors - Leaded DLFL Saturat choke 8A Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 20
500 uH 8 A Radial + 100 C
Schurter RF inductors - Leaded SATURATING Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 2

200 uH 15 % 45 A Radial + 100 C
Schurter RF inductors - Leaded SATURATING Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 10

150 uH 15 % 25 A Radial + 100 C
Schurter RF inductors - Leaded DLFL Saturat choke 35A Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 10
50 uH 15 % 35 A Radial + 100 C
Schurter Common Mode Chokes / Filters SATURATING Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 10

1 mH 5 A Wire + 100 C
Schurter Common Mode Chokes / Filters DLFP Saturat choke 8A Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 10

500 uH 8 A Wire + 100 C
Schurter Common Mode Chokes / Filters DLFP Saturat choke 45A Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 2
200 uH 45 A Wire + 100 C
Schurter Common Mode Chokes / Filters SATURATING Non-Stocked Lead-Time 12 Weeks
Min.: 504
Mult.: 6

500 uH 12 A Wire + 100 C
Schurter Power Inductors - Leaded DS Storage choke 3.15A Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 20
1 nH 3.15 A Radial + 125 C
Schurter Power Inductors - Leaded DS Storage choke 4A Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 20
500 uH 4 A Radial + 125 C
Schurter Power Inductors - Leaded DSO Storage choke 6A Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 50
100 uH 15 % 6 A Radial + 125 C
Schurter Power Inductors - Leaded DSO STORAGE CHOKE 4A 500H Non-Stocked Lead-Time 12 Weeks
Min.: 500
Mult.: 50
500 uH 4 A Radial + 125 C